@@ -0,0 +1,42 @@
|
|
|
+## UI for IR6500 BGA Rework Station
|
|
|
+##
|
|
|
+
|
|
|
+Dependencies:
|
|
|
+
|
|
|
+PyQT5
|
|
|
+pyqtgraph
|
|
|
+pyserial
|
|
|
+
|
|
|
+To run:
|
|
|
+
|
|
|
+'''
|
|
|
+cd pc410
|
|
|
+python3 src/main/python/main.py
|
|
|
+'''
|
|
|
+
|
|
|
+Each row in the table below is one program.
|
|
|
+Click on row to show graph representing temperature curve.
|
|
|
+Drag in graph to edit parameters, table will update automatically.
|
|
|
+
|
|
|
+r-columns are rate in degrees C/second.
|
|
|
+l-columns are level ie target temperature for each step
|
|
|
+t-columns are dwell time ie how long to stay at the target temperature before continuing.
|
|
|
+
|
|
|
+Each program has 8 steps.
|
|
|
+If rate is 0.0 this means STEP which ignores the rate slope and goes straight to dwell time.
|
|
|
+If rate is -0.01 this means END which makes the program end at that step.
|
|
|
+The PC410 controller can also chain programs together but that is not implemented here yet.
|
|
|
+
|
|
|
+Save will save the current settings to .pc410Settings in the HOME-directory. This file will always be loaded when the program starts.
|
|
|
+
|
|
|
+Add row will add an empty row at the end or after the currently selected row, if any.
|
|
|
+Run will start running the program and then also plot the current temperature over time as it runs.
|
|
|
+Stop will stop the runnin program.
|
|
|
+Start button and stop button on IR6500 will have the same effect.
|
|
|
+Read program reads the parameters of the current program into the selected line on the table, or to a new line if none was selected.
|
|
|
+Write program will write the parameters from the selected line to the IR6500.
|
|
|
+
|
|
|
+The IR6500 has 9 program slots but since I haven't been able to figure out how to select or know which slot is selected over the serial interface all read/write operations work on the currently selected slot.
|
|
|
+
|
|
|
+The clock shows time passed since run started.
|
|
|
+Bottom right shows all the state paramters from the PC410
|