## UI for IR6500 BGA Rework Station ## Dependencies: ``` PyQT5 pyqtgraph pyserial ``` To run: ``` cd pc410 python3 src/main/python/main.py ``` Each row in the table is one program. Click on row to show an interactive graph representing the temperature curve of the program. One program is up to 8 segments. Each segment has a slope (degrees pers second until target temperature level) and a horizontal section(dwell time at target temperature level). Drag nodes in the graph to edit parameters and the table will update automatically. * r-columns are slope rate in degrees C/second. * l-columns are target temperature level for each step * t-columns are dwell time ie how long to stay at the target temperature level before continuing with the next slope. If a rate is 0.0 this means STEP which ignores the rate slope and goes straight to dwell time. If a rate is -0.01 this means END which makes the program end at that step. The PC410 controller can also chain programs together but that is not implemented here yet. ### Actions #### Save Save will save the current settings to .pc410Settings in the HOME-directory. This file will always be loaded when the program starts. #### Add row Add row will add an empty row at the end or after the currently selected row, if any. #### Run Run will start running the program and then also plot the current temperature over time as it runs. Start button on the IR6500 will have the same effect. #### Stop Stop will stop the running program. Stop button on the IR6500 will have the same effect. #### Read program Read program reads the parameters of the current program into the selected line on the table, or to a new line if none was selected. #### Write program Write program will write the parameters from the selected line to the IR6500. The IR6500 has 9 program slots but since I haven't been able to figure out how to select or know which slot is selected over the serial interface all read/write operations work on the currently selected slot. The clock shows time passed since run started. Bottom right shows all the state parameters from the PC410 ### Bottom heater The bottom heater on the IR6500 is controller by another PID and can not be controlled from here ### Documentation The docs folder contains the PDF manual for the IR6500 itself, for the PC410 module as well as for a AL808-module which is documenting the communication protocol also used by PC410.