@@ -30,16 +30,24 @@ If rate is 0.0 this means STEP which ignores the rate slope and goes straight to
|
|
|
If rate is -0.01 this means END which makes the program end at that step.
|
|
|
The PC410 controller can also chain programs together but that is not implemented here yet.
|
|
|
|
|
|
+*** Buttons ***
|
|
|
Save will save the current settings to .pc410Settings in the HOME-directory. This file will always be loaded when the program starts.
|
|
|
|
|
|
Add row will add an empty row at the end or after the currently selected row, if any.
|
|
|
-Run will start running the program and then also plot the current temperature over time as it runs.
|
|
|
-Stop will stop the runnin program.
|
|
|
-Start button and stop button on IR6500 will have the same effect.
|
|
|
+
|
|
|
+Run will start running the program and then also plot the current temperature over time as it runs. Start button on the IR6500 will have the same effect.
|
|
|
+
|
|
|
+Stop will stop the running program. Stop button on the IR6500 will have the same effect.
|
|
|
+
|
|
|
Read program reads the parameters of the current program into the selected line on the table, or to a new line if none was selected.
|
|
|
+
|
|
|
Write program will write the parameters from the selected line to the IR6500.
|
|
|
|
|
|
The IR6500 has 9 program slots but since I haven't been able to figure out how to select or know which slot is selected over the serial interface all read/write operations work on the currently selected slot.
|
|
|
|
|
|
The clock shows time passed since run started.
|
|
|
-Bottom right shows all the state paramters from the PC410
|
|
|
+
|
|
|
+Bottom right shows all the state parameters from the PC410
|
|
|
+
|
|
|
+*** Bottom heater ***
|
|
|
+The bottom heater on the IR6500 is controller by another PID and can not be controlled from here
|